Model sp-320-12
Output dcvoltage 12V
Ratedcurrent 25A
Currentrange 0~25A
Ratedpower 300W
Ripple & noise (max. ) note. 2 150MVP-p
Voltageadj. Range 10~13.2V
Voltage tolerance note. 3 ± 1.0%
Lineregulation ± 0.3%
Loadregulation ± 0.5%
Setup, rise time 800ms, 50ms/230vac 1200, 30ms/115vac at full load
Hold, time(typ. ) 16ms/230vac 16ms/115vac at full load
Input voltagerange 88~264vac 124~370vdc
Frequencyrange 47~63Hz
Power factor (typ. ) pf>0.93/230vac pf>0.98/115vac at full load
Efficiency (typ. ) 86%
115vac 5A
AC current (typ. ) 230vac 2.5A
Inrush current (typ. ) 20A/115vac 40A/230vac
Leakagecurrent <1ma/240vac
Protection overload 105~135%rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over voltage 13.8~16.2V
Protection type: Shut down o/p voltage, re-power on to recover
Over temperature 80c~± 5c(70c± 5c 3.3V, 5vonly) (tsw1: Detect on heatsink of power transistor)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
Environment working temp. -20~+65c (refer to output load derating curve)
Working humidity 20~90% rh non-condensing
Storage temp humidity -40~+85c 10~95%rh
Tempcoefficient ± 0.03%(0~50c)
Vibration 10~500Hz, 2g10min/1cycle, 60min. Each alongx, y, zaxes
Safety & EMC safety standards UL60950-1, TUV en60950-1 approved
Withstand voltage 1/p-0/p: 3kvac 1/p-fg: 1.5kvac 0/p-fg: 0.5kvac
Isolationresistance 1/p-0/p, 1/p-fg, 0/p-fg: 100m ohms/500vdc
EMI conducticn & Radiation compliance to en55022(cispr22)classb
Harmoniccurrent compliance to en61000-3-2, -3
EMS immunity compliance to en61000-4-2, 3, 4, 5, 6, 8, 11 env50204, en55024, light industry level criteriaa
Qthers mtbf 207khrs min mil-hdbk-217f(25c)
Dimension 215*115*50mm(l*w*h)
Packing 1.1g; 12PCS / 14kg / 0.92cuft
Note
1. All parameters not specially mentioned are measured at 230vac input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: Includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
Switching Power Supply (SP-320-12)